Consumables for 3D mapping system and electrophysiology consumables
Publication (OJ)
Submission Deadline
Procedure Type
Lots
Buyer headquarters
Sector
Description
consumables for 3D mapping system and electrophysiology consumables
CPV Codes
Lots (20)
Ablation catheter compatible with 3D mapping system, with contact force measurement sensor, total number of electrodes 6 (six), distal electrode length 3.5mm, possibility of selecting 3 (three) or more curves, magnetic mapping sensor
Award criteria
Multipolar diagnostic mapping catheter compatible with 3D mapping system, diameter 7F, minimum 20 electrodes at 2-6-2 mm spacing, catheter length 115 cm.
Award criteria
Multipolar diagnostic catheter, diameter 8F, with 48 electrodes, choice of D and F curves, compatible with 3D system "Carto"
Award criteria
Cables for diagnostic multipolar catheter "Octaray" - compatible with 3D mapping system
Award criteria
Дефлектибилен воведник со должина 71cm, со можност за избор од 3 кривини (мала, средна, голема), кои може да се визуелизираат на CARTO системот.
Award criteria
Tubing set for irrigation compatible with “Smart ablate” pump
Award criteria
Electrode compatible with 3D mapping system “CARTO”
Award criteria
Ablation bi-directional catheter compatible with 3D mapping system, with contact force measurement sensor, total number of electrodes 4 (four), with electrode spacing of 2-2-2, distal electrode length 4mm, possibility of selecting 2 (two) or more curves, magnetic mapping sensor and flexible tip and length of 115cm.
Award criteria
Multipolar deflectable diagnostic mapping catheter compatible with 3D mapping system, diameter 7.5F, minimum 16 electrodes, 1mm in size, 3mm apart, catheter length 110 cm.
Award criteria
Tubing set for irrigation compatible with the “Cool Point” pump, and the “Ampere RF” radiofrequency generator.
Award criteria
Electrode compatible with 3D mapping system "Ensite X"
Award criteria
Introducer "side port" - set with wire and needle, with the possibility of choosing dimensions when ordering from 6-10F, with mandatory representation of all dimensions
Award criteria
Long introducer with a length of 63-81cm, internal diameter 8 and 8.5F, at least 3 different curves, hemostatic valve and atraumatic soft tip.
Award criteria
Long introducer with a length of 63-81cm, inner diameter 8 and 8.5F, at least 5 different curves, hemostatic valve and transseptal puncture needle with an extremely sharp tip (Xs), 18 Gauge with a length of 71-98cm, guide wire.
Award criteria
Catheter with a diameter of 8.5F with variable curvature in two directions, one opposite the other, asymmetrical bending, in one direction 90° and in the other direction 180°
Award criteria
Quadripolar diagnostic catheter, thickness (5F and 6F), length 110-115, fixed curvature Josephson, Josephson special, Damato, Cournand or equivalent, optional with atraumatic soft tip, electrode spacing, 2mm, 5mm, 10mm or 2-5-2mm.
Award criteria
Cable compatible with quadripolar diagnostic catheter (described in issue 16)
Award criteria
Distance between electrodes 2-6-2mm or 2-8-2mm, length 90-115cm, thickness not greater than 7F, D-F curvature
Award criteria
Cable compatible with a deflectable diagnostic catheter (described in issue 18)
Award criteria
IBP measurement line set, for connection to multiple pressure transducer SP844 with matching dome
Award criteria